Element OS KBs
Element OS KBs
Featured
Cannot Communicate with Node ID
SolidFire Application cannot communicate with node ID
SolidFire Application cannot communicate with node ID
Cluster Not Reporting
How to troubleshoot Cluster Not Reporting Alert
How to troubleshoot Cluster Not Reporting Alert
Upgrade Pre-Checks
SolidFire and HCI Cluster upgrade pre-checks for all upgrades
SolidFire and HCI Cluster upgrade pre-checks for all upgrades
Support Bundle
How to collect a support bundle from a SolidFire or HCI storage cluster
How to collect a support bundle from a SolidFire or HCI storage cluster
Can't Login?
Not able to log into Cluster UI after upgrade to Element software
Not able to log into Cluster UI after upgrade to Element software
Async Delay
Replicating volume pairs have an Async Delay greater than 360 minutes
Replicating volume pairs have an Async Delay greater than 360 minutes
Other Resources
- Why does Block Capacity and Provisioned Space have the same value in the Cluster UI?Thu, 26 Dec 2024
- Why there are extra compute nodes that doesn't belong to the clusterThu, 26 Dec 2024
- xDBConnectionLoss trap is sent with no alert during upgradeThu, 26 Dec 2024
- What is changing with SolidFire Active IQ alert notification emails?Thu, 26 Dec 2024
- What is supported with NetApp HCI and VMware ESXi version 8.0 and beyond?Thu, 26 Dec 2024
- What is the latest Element OS a SolidFire cluster with FC nodes can be upgraded toThu, 26 Dec 2024
- What is the NDE version included in the Element OS 12.7?Thu, 26 Dec 2024
- Volume Size displayed in cluster UI and Active IQ is larger than expectedThu, 26 Dec 2024
- Warning reporting messages "Bad signal integrity error" on Mellanox switchThu, 26 Dec 2024
- Weak SSL/TLS Key Exchange - CVE-2016-2183Thu, 26 Dec 2024
- What is the expected bandwidth/throughput of a Solidfire NodeThu, 26 Dec 2024
- What is the latest EOS version we can install to H410S platform?Thu, 26 Dec 2024
- Unexpected Exception and volumesDegraded alerts are detectedThu, 26 Dec 2024
- Upgrade of Element software fails after single node completesThu, 26 Dec 2024
- vCenter Plug-in Unexpected error: No thread-bound request foundThu, 26 Dec 2024
- vCenter Plugin Registration fails with error: A vcenter is already registered with the pluginThu, 26 Dec 2024
- VDI provisioning getting failed due to degraded volume performanceThu, 26 Dec 2024
- VEEAM backups fails with error Attributes are nullThu, 26 Dec 2024
- VMware error message resource cluster metadata corruption has been detectedThu, 26 Dec 2024
- Volumes Go Degraded While Collecting Support BundleThu, 26 Dec 2024
- How to check the assigned VLAN IP address of each storage node and will these IP be changed in any scenario?Thu, 26 Mar 2026
- How to ssh to a cluster node running Element version 12.5 or greaterThu, 03 Jul 2025
- How To Reboot An NetApp HCI Management NodeThu, 26 Dec 2024
- How To Verify and Download the latest Element SoftwareThu, 26 Dec 2024
- Login errors using admin credentials: Cluster UI and mNode UIThu, 26 Dec 2024
- How To Free Up Storage Capacity for an HCI Storage ClusterThu, 26 Dec 2024
- How to reboot an Element storage nodeThu, 26 Dec 2024
- Unable to add SolidFire cluster on VCP with vCenter Linked ModeThu, 26 Dec 2024
- How To Enable SSH On SolidFire/HCI Management NodesThu, 26 Dec 2024
- How to abort an Element software upgrade with the mNode REST APIThu, 26 Dec 2024
- How to create user and role for Element Plugin for vCenter Server (VCP) 5.0Thu, 26 Dec 2024
- How To Upgrade NetApp Hybrid Cloud Control Management ServicesThu, 26 Dec 2024
- How To Create an Accessible Data Volume for an HCI Storage ClusterThu, 26 Dec 2024
- Remote replication volume pairs in pausedDisconnected statusThu, 26 Dec 2024
- How to suppress alerts in SolidFire Active IQThu, 26 Dec 2024
- AutoSupport Message: 'System memory is very low' on Element software 12.0 and aboveThu, 26 Dec 2024
- Element Create Datastore Operation fails due to volume not visible to hostThu, 26 Dec 2024
- How to check the version of management services for HCCThu, 26 Dec 2024
- Replacement Storage Node Not Showing Under PendingActiveThu, 26 Dec 2024
- NetApp SolidFire node reports PCIe Error : Bus Correctable/Uncorrectable ErrorThu, 26 Dec 2024
