Skip to main content

NetApp Stage KB

Node panic reboot due to DIMM ECC error

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

Applies to

  • ONTAP 9
  • FAS systems
  • AFF systems

Issue

  • Node panic reboot with DIMM ECC error:

PANIC: ECC error at DIMM-2: CE-01-2226-0354E55F,ADDR 0x824d1c100,(Node(0), Memory controller(0), CH(1), DIMM(0), Rank(1), Bank Group(3), Bank(0x1), Row(0xf929), Col(0x218)), devtag(0x3f), correrr(0x0) Uncorrectable Machine Check Error at CPU11.

  • After reboot DIMM show 0 error count.

::> system controller memory dimm show -node *

              DIMM     UECC  CECC  Alert  CPU           Slot          Failure
Node          Name    Count Count Method Socket Channel Number Status    Reason
------------- ------- ----- ----- ------ ------ ------- ------ ------- --------
node1
              DIMM-1      0     0 bucket      0       0     0 ok          none
              DIMM-2      0     0 bucket      0       1      0 ok          none

2 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.