Skip to main content

NetApp Stage KB

Node panic by battery failure

Views:
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
HW
Last Updated:

Applies to

AFF-C190

Issue

  • Node panic.
  • events all reports env_mgr triggers OS halt.

Record 590: Sun May 21 16:25:51.590000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery temp critical
Record 591: Sun May 21 16:25:51.600000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery initial FCC f
Record 592: Sun May 21 16:25:58.000000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery voltage criti
Record 593: Sun May 21 16:25:58.930000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery current criti
Record 594: Sun May 21 16:25:58.940000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery charging curr
Record 595: Sun May 21 16:26:22.270000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery discharge FET
Record 596: Sun May 21 16:26:30.230000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery charging volt
Record 597: Sun May 21 16:26:30.240000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery charge FET fa
Record 598: Sun May 21 16:26:43.960000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery full capacity
Record 599: Sun May 21 16:26:47.110000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery remain capaci
Record 600: Sun May 21 16:28:30.230000 2023 [IPMI.emergency]: env_mgr triggers OS halt:Battery pack invalid

  • system sensors report battery is not readable.

Bat_Temp         | na         | degrees C  | na         | 0.000     | 5.000     | 56.000    | 60.000    
Bat_Volt         | na         | Volts      | na         | 5.500     | 5.600     | 8.500     | 8.600     
Bat_Curr         | na         | Amps       | na         | na        | na        | 1.520     | 1.800     
Bat_Rem_Cap      | na         | Amps * hour | na         | na        | na        | na        | na        
Bat_Full_Cap     | na         | Amps * hour | na         | na        | na        | na        | na        
Bat_Charge_Curr  | na         | Amps       | na         | na        | na        | 2.400     | 2.900     
Bat_Charge_Volt  | na         | Volts      | na         | na        | na        | 8.900     | 9.000     
Bat_Design_Cap   | na         | Amps * hour | na         | na        | na        | na        | na        
Bat_Initial_Fcc  | na         | Amps * hour | na         | na        | na        | na        | na        
Bat_Average_Temp | na         | degrees C  | na         | na        | na        | na        | na        
Bat_Rem_Cap_off  | na         | Amps * hour | na         | na        | na        | na        | na        
Bat_Dstg_Cycles  | na         | cycles     | na         | 2.000     | 5.000     | na        | na        
Bat_Power_Fault  | 0x0        | discrete   | Deasserted | na        | na        | na        | na        
Bat_Dsg_FET_Flt  | na         | discrete   | na         | na        | na        | na        | na        
Bat_Chg_FET_Flt  | na         | discrete   | na         | na        | na        | na        | na        
Bat_Pack_Invalid | na         | discrete   | na         | na        | na        | na        | na        
Bat_Cycle_Cnt    | na         | cycles     | na         | na        | na        | na        | na        
Bat_Lrn_Active   | na         | discrete   | na         | na        | na        | na        | na       

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.