NVDIMMBadHealthAlert on AFF-A800, AFF-A320, AFF-A400, FAS8300, FAS8700
Applies to
- ONTAP 9
- AFF A800, AFF A400, AFF A320
- FAS8700, FAS8300
- NVDIMM
Issue
EMS:
Sun Jun 06 17:17:15 -0700 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller
AutoSupport Section: NVDIMM-STATUS
Example:
Total NVDIMM on this platform is 1 -------------------------------------------------- DIMM(/dev/nvdimm0) Page:0 -------------------------------------------------- 0x0000: 00 0a 0a 01 01 00 21 3c 25 3c 25 34 34 00 00 00 0x0010: 1f 2e 00 00 03 15 03 0b 68 81 02 00 68 81 1e 80 0x0020: 05 80 78 80 05 00 00 40 1f ac 0d d0 07 a0 0f 90 0x0030: 33 08 08 dc 05 10 80 00 00 00 70 03 00 00 00 00 0x0040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0060: a5 00 00 00 00 00 00 00 01 00 04 00 00 00 00 00 0x0070: 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0080: 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0090: 01 00 00 00 00 00 00 00 0a 00 00 00 00 00 00 00 0x00a0: 01 40 00 00 00 00 00 00 00 00 01 00 00 00 00 00 0x00b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00c0: 56 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x00f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ----------------------------------------------------- -------------------------------------------------- DIMM(/dev/nvdimm0): -------------------------------------------------- Controller Ready: Yes Controller Busy: No Energy Policy managed by: HOST Save_N Low During CSAVE: Yes Save_N Enabled(ARMED): Yes Data on the Flash: NotValid Module is Health: No Module Status(0x0040): NVDIMM FIRMWARE error <------------- Flash Lifetime: 86% Flash Lifetime Status: Normal
Example Health Alert:
::>system health alert show
| Node | NetApp1 |
|---|---|
| Monitor | controller |
| Alert ID | NVDIMMBadHealthAlert |
| Alerting Resource | /dev/nvdimm0:NetApp1 |
| Subsystem | Motherboard |
| Indication Time | Sun Jun 06 17:17:15 2021 |
| Perceived Severity | Major |
| Probable Cause | hardware_degrading |
| Description | NVDIMM "NVDIMM-N 0 (DIMM-11)" on node "NetApp1" is indicating a degraded status. |
| Corrective Actions | Contact technical support for assistance with NVDIMM module replacement. |
| Possible Effect | Potential data loss as the NVDIMM becomes degraded. |
| Acknowledge | false |
| Suppress | false |
| Policy | NVDIMMBadHealthPolicy |
| Acknowledger | |
| Suppressor | |
| Additional Information |
Node: NetApp1 |