Skip to main content
NetApp Stage KB

Remote disks reporting as failed only by one node in Metrocluster IP

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

 

 

 

 

Applies to

  • ONTAP 9
  • MCC-IP

Issue

  • One node is reporting a few remote disks as failed.

cluster1::> system node run -node cluster1_node01 -command sysconfig -a

        slot 0: Virtual iSCSI Host Adapter 0m
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D) (Failed)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM) (Failed)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ) (Failed)
        slot 0: Virtual iSCSI Host Adapter 0v
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D) (Failed)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM) (Failed)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ) (Failed)

  • Its partner node and the DR site nodes are reporting the disks as normal.

cluster1::> system node run -node cluster1_node02 -command sysconfig -a

        slot 0: Virtual iSCSI Host Adapter 0m
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)
        slot 0: Virtual iSCSI Host Adapter 0v                            
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)

cluster2::> system node run -node cluster2_node01 -command sysconfig -a

        slot 0: SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)
        slot 0: SAS Host Adapter 0d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
                10.9 : NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
                10.12: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
                10.13: NETAPP   X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • Was this article helpful?