Does Brocade Defect FOS-817953 affect MetroCluster backend switches?

Views:
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
MetroCluster
Last Updated:

 

 

Applies to

  • MetroCluster
  • Brocade

Answer

FOS-817953 is triggered by the use of the command network fcp zone show. This command does not query MetroCluster backend switches but only frontend SAN switches. 

Configuration details in a MetroCluster backend configuration are received via SNMP not via the network fcp zone show command. 

MetroCluster backend switches are not exposed to Brocade Defect FOS-817953.

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.