All nodes in Metrocluster report adapterHardwareErrorEMSOnly error for mediator disks
Applies to
- ONTAP 9
- MetroCluster IP
- Mediator
Issue
All nodes in MetroCluster report adapterHardwareErrorEMSOnly for the mediator disks.
[site1-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c0:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]