Skip to main content
NetApp Stage KB

All nodes in Metrocluster report adapterHardwareErrorEMSOnly error for mediator disks

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

 

Applies to

  • ONTAP 9
  • MetroCluster IP
  • Mediator

Issue

All nodes in MetroCluster report adapterHardwareErrorEMSOnly for the mediator disks.

[site1-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.0 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site1-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.0 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site2-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.3 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.2 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site2-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c0:0008. Disk 0f.3 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2-node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.2 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.