Skip to main content
NetApp Stage KB

ATTO Fibre Bridge causing Link Failures on FC switch

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

 

 

Applies to

  • Fabric MetroCluster
  • ATTO FB7500

Issue

  • Many link failure errors are observed on the switch ports connected to this ATTO bridge:
    • 2021/04/13-15:17:49, [PORT-1003], 111567, FID 128, WARNING, FabSW1, Port 11 Faulted because of many Link Failures.
  • The ATTO bridge itself cannot obtain FC port error counts:
    • get FCPortErrors all

      ; Fibre Channel Error Counts
      ; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC
      ;==========================================================================
         1        Error Obtaining FC Error Counts for port 1
         2        Error Obtaining FC Error Counts for port 2

  • Health Monitor reports the ATTO bridge in an 'error' state:
    • ClusterA::> storage bridge show
                                                                  Is        Monitor
      Bridge     Symbolic Name Vendor  Model     Bridge WWN       Monitored Status
      ---------- ------------- ------- --------- ---------------- --------- -------
      ATTO_0.0.0.16
                 FB-16
                               Atto    FibreBridge 7500N
                                                 2000001086603824 true      ok
      ATTO_0.0.0.17
                 FB-17         Atto    FibreBridge 7500N
                                                 20000010866037e8 true      error
      ATTO_0.0.0.18
                 FB-18         Atto    FibreBridge 7500N
                                                 2000001086609e0e true      ok
      ATTO_0.0.0.19
                 FB-19         Atto    FibreBridge 7500N
                                                 2000001086609c06 true      ok
  • Sysconfig -a does not report the ATTO bridge under any of the adapters.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 