Skip to main content
NetApp Stage KB

Bug 1331200 ATTO 7500NN/7600N FibreBridge fails to be added to monitoring

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

 

 

Applies to

  • ATTO 7500N FibreBridge
  • ATTO 7600N FibreBridge
  • ONTAP 9

Issue

  • ATTO FibreBridge can not be added to in-band monitoring and fails with "Error: command failed: entry doesn't exist"

ClusterA::> storage bridge add -address 0.0.0.0 -managed-by in-band -name ATTO_FibreBridge7500N_3
Error: command failed: entry doesn't exist

  • sktrace logs show following messages
KSMF_SMF_SVC_NORM:   process_request: Processing for table kern_storage_bridge took 10000 msec which is longer than the client's timeout of 5000
  • Performance issues may exist:
    • They will be noted in Network Processing in Unified Manager, CPU nblade, or the Network column of qos statistics volume latency show:
    • ::> qos statistics volume latency show -volume vol1 -vserver svm1 -iterations 3
      Workload            ID    Latency    Network    Cluster       Data       Disk        QoS      NVRAM      Cloud  FlexCache    SM Sync
      --------------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ----------
      -total-              -      4.33s      4.33s   195.00us   468.00us        0ms        0ms        0ms        0ms        0ms        0ms
      vol1-wid17759    17759      4.33s      4.33s   195.00us   468.00us        0ms        0ms        0ms        0ms        0ms        0ms
      -total-              -      9.26s      9.26s   141.00us    17.00us        0ms        0ms        0ms        0ms        0ms        0ms
      vol1-wid17759    17759      9.26s      9.26s   141.00us    17.00us        0ms        0ms        0ms        0ms        0ms        0ms
      -total-              -      9.26s      9.26s   141.00us    25.00us        0ms        0ms        0ms        0ms        0ms        0ms
      vol1-wid17759    17759      9.26s      9.26s   141.00us    25.00us        0ms        0ms        0ms        0ms        0ms        0ms
      

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.