Problem on ADVA device causing reset on FCVI ports and ISL CRC errors
Applies to
- MetroCluster FC
- ISL - ADVA - smal ADVA
- Brocade switch
Issue
- FCVI reset on two ports on two different controller in one cluster
- FCVI port flapping
Fri Jan 02 04:04:22 +0100 [cl01n31: ispfcvi2500_port1: fcvi.link.up:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '210034800d20dbf8'}Fri Jan 02 12:47:04 +0100 [cl01n31: ispfcvi2500_port1: fcvi.link.down:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '210034800d20dbf8', 'alertingResourceName': '2a', 'possibleEffect': 'DR protection of NVRAM mirror might be compromised.', 'probableCause': 'Cable_tamper', 'probableCauseDescription': 'Physical link on port 2a is offline.', 'additionalInfo': 'None'}- Fast increasing CRC error on ISL ports on Brocade switch