Applies to

  • MetroCluster
  • Lifs that have "-mc" appended as apart of MetroCluster 

Answer

Yes, these lifs must be re-homed and migrated manually.
::> network interface modify -vserver <vserver> -lif <lif> -home-port <port> -home-node <node>
::> network interface revert  -vserver <vserver> -lif <lif>
 
Once moved, ensure the configuration is checked.
::> metrocluster check run
::> metrocluster check show

Additional Information

additionalInformation_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.