Skip to main content
NetApp Stage KB

Node panic due to mSATA Read Error: PciRoot(0x0)

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • AFF-A300
  • ONTAP 9.3P12

Issue

  • Node panics with mgwd unresponsive.

PANIC: Process mgwd unresponsive for 696 seconds in process nodewatchdog on release 9.3P12 (C)

  • System log console output.

pages: I/O read error
g_vfs_done():md0.uzip[READ(offset=358678528, length=4096)]error = 6
vnode_pager_getpages: I/O read error
g_vfs_done():md0.uzip[READ(offset=347963392, length=4096)]error = 6
vnode_pager_getpages: I/O read error

mSATA Read Error: PciRoot(0x0)/Pci(0x1F,0x2)/Sata(0x0,0x0,0x0)
[SysFW.critical]: mSATA Read Error: PciRoot(0x0)/Pci(0x1F,0x2)/Sata(0x0,0x0,0x0)
ERROR: Error booting OS on: 'boot0' file: fat://boot0/X86_64/freebsd/image1/kernel (boot0,fat)

  • SP_IPMI log.

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                                     fault reason                                    count  time
---- ------- ----                                    -------------                                   ------ -----
1    0x5     /chassis-1/controller-a                 OS is not booted                                1      
2    0x1     /chassis-1/controller-a/boot-1          Disk read error                                 1      
Fault Lights On:
             /chassis-1                                                                              2
             /chassis-1/controller-a                                                                 2
             /chassis-1/controller-a/boot-1                                                          1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.