AFF-A220

Issue

AFFA220 shuts down with battery not charging alerts:

Event logs:
Record 406: Sun Apr 07 15:34:18.550000 2024 [IPMI.emergency]: env_mgr triggers OS halt:Battery not charging
Record 407: Sun Apr 07 15:34:53.660000 2024 [IPMI.notice]: 01a3 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
Record 408: Sun Apr 07 15:34:55.000000 2024 [Controller.notice]: Appliance user command halt.
Record 409: Sun Apr 07 15:34:53.680000 2024 [IPMI Event.critical]: System power down
Record 410: Sun Apr 07 15:34:54.030000 2024 [IPMI.emergency]: Data ONTAP initiated shutdown
Record 411: Sun Apr 07 15:34:54.030000 2024 [Trap Event.critical]: hwassist abnormal_reboot (28)


Console logs:
Apr 07 13:00:08 [callhome.battery.failure:EMERGENCY]: Call home for BATTERY (no charge) CRITICAL.
Apr 07 13:22:59 [callhome.battery.failure:EMERGENCY]: Call home for BATTERY (no charge) CRITICAL.
Apr 07 13:48:40 [callhome.battery.failure:EMERGENCY]: Call home for BATTERY (no charge) CRITICAL.
Apr 07 14:09:21 [callhome.battery.failure:EMERGENCY]: Call home for BATTERY (no charge) CRITICAL.
Apr 07 15:34:24 [monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery not charging)

However, sensor readings don't display Battery issues. 

Bat_Temp         | 24.000     | degrees C  | ok         | 0.000     | 5.000     | 56.000    | 60.000
Bat_Volt         | 8.100      | Volts      | ok         | 5.500     | 5.600     | 8.500     | 8.600
Bat_Curr         | 0.000      | Amps       | ok         | na        | na        | 1.520     | 1.800
Bat_Rem_Cap      | 1.536      | Amps * hour | ok         | na        | na        | na        | na
Bat_Full_Cap     | 1.536      | Amps * hour | ok         | na        | na        | na        | na
Bat_Charge_Curr  | 1.000      | Amps       | ok         | na        | na        | 2.400     | 2.900
Bat_Charge_Volt  | 8.200      | Volts      | ok         | na        | na        | 8.900     | 9.000
Bat_Design_Cap   | 2.100      | Amps * hour | ok         | na        | na        | na        | na
Bat_Initial_Fcc  | 1.700      | Amps * hour | ok         | na        | na        | na        | na
Bat_Average_Temp | 24.000     | degrees C  | ok         | na        | na        | na        | na
Bat_Rem_Cap_off  | 0.120      | Amps * hour | ok         | na        | na        | na        | na
Bat_Dstg_Cycles  | 51.000     | cycles     | ok         | 2.000     | 5.000     | na        | na

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.