Skip to main content
NetApp Stage KB

MetroCluster why do Circle and Square ports show as empty in storage shelf show -instance?

Views:
1
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

 

Applies to

  • Fabric MetroCluster
  • ONTAP 9

Answer

Because of the way the shelves are cabled the end shelves or only shelf in a stack will have the circle or square port empty on IOM A or IOM B.
In this example the square port is empty in IOM B of shelf 30 and the circle port is empty in IOM A of shelf 39:
 
Shelf name:    switch1:11.shelf30 <<< first shelf in the stack
Shelf id:      30
Channel:       switch1:11
Module:        B
Shelf UID:     50:0d:09:88:03:51:e7:04
Shelf S/N:     6500264603
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK
 
Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk    Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id     State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[SQR0] EMPTY          7         NA        0           0       0        0         0       1
[SQR1] EMPTY          7         NA        0           0       0        0         0       1
[SQR2] EMPTY          7         NA        0           0       0        0         0       1
[SQR3] EMPTY          7         NA        0           0       0        0         0       1
[CIR4] OK             7        6.0        0           0       0        0         0       1
[CIR5] OK             7        6.0        0           0       0        0         0       1
[CIR6] OK             7        6.0        0           0       0        0         0       1
[CIR7] OK             7        6.0        0           0       0        0         0       1
 
Shelf name:    switch1:10.shelf39 <<< last shelf in the stack
Shelf id:      38
Channel:       switch1-fsw2:10
Module:        A
Shelf UID:     50:0d:09:88:01:2d:d6:00
Shelf S/N:     6500125972
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK
 
Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk    Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id     State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[SQR0] OK             7        6.0        0           0       0        0         0       1
[SQR1] OK             7        6.0        0           0       0        0         0       1
[SQR2] OK             7        6.0        0           0       0        0         0       1
[SQR3] OK             7        6.0        0           0       0        0         0       1
[CIR4] EMPTY          7         NA        0           0       0        0         0       1
[CIR5] EMPTY          7         NA        0           0       0        0         0       1
[CIR6] EMPTY          7         NA        0           0       0        0         0       1
[CIR7] EMPTY          7         NA        0           0       0        0         0       1
 

Additional Information

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
c19f1b8b-4901-43b6-a9b5-d09a2d57cdd0