Different FC ports offline after ISL misbehaving because of errors
Applies to
- MetroCluster FC
- BrocadeG620
- Brocade v8.2.3c1
Issue
- In
sysconfig -awe see following:- Many FC ports offline
Link Data Rate: N/A
Switch Port: ??
- On switch side the ports showing
TX Power: -40.0 dBm (0.1 uW) - In Event log show we see the errors:
Sun Jun 01 00:09:31 +0200 [NodeN02: isp2400_timeout_7: fci.device.quiesce:debug]: Adapter xxa encountered a command timeout on Disk device SwitchB01:9.126 (0x0c050900) LUN 1016 cdb 0x9a:000000003d9ae758:0001:0068 retry: 0 Quiescing the device.
Sun Jun 01 00:09:32 +0200 [NodeN02: isp2400_timeout_7: fci.device.timeout:debug]: HBA xxa encountered a device timeout on Disk device SwitchB01:9.126 (0x0c050900) LUN 1016 cdb 0x9a:000000003d9ae758:0001:0068 retry: 0
- Switch showing the ports connected to all FC ports to be in
No_Syncstate showingSwitch not ready for F or L ports - ISL ports showing errors