E-Series controller gets offline due to DA mismatch on cache by requests to NVMe volumes
Applies to
- E-Series systems EF300, EF600
- SANtricity OS 11.90R2 or earlier
- Data Assurance (DA)
- NVMe (Non-Volatile Memory Express)
- NVMe Deallocated or Unwritten Logical Block Error Enable (DULBE)
- Write Caching is enabled for the volume
Issue
- E-Series controller gets offline after detecting multiple events showing DA mismatch on the cached data for NVMe volumes
Event type: 2061
Event category: Error
Priority: Informational
Description: Data assurance mismatch detected - probable cause is cached data
Event specific codes: 0/0/0
Component type: Volume
Component location: Volume <VOLUME>
Logged by: Controller in bay <A/B>
E-Series Notification (Loss of host-side connection redundancy detected) CRITICALis triggered