Issue
- E-Series SANtricity System Manager or Storage Manager's indicates array is in needs attention state with one or more of the following entries in the recovery guru:
Individual Drive - Degraded PathController Drive Channel DegradedDEGRADED_DRIVE_CHANNEL-Recovery Failure Type Code: 71DEGRADED_DRIVE_PATH-Recovery Failure Type Code: 76NO_REDUNDANCY_DRIVE-Recovery Failure Type Code: 32
Major event logreports one or more of the following:Drive path redundancy lost - Tray 99, Drawer X, Slot XFibre Channel Destination Error - Redundant Path is not available to Device
- These steps can also be applied for
Failure Entry 1: BYPASSED_DRIVE-Recovery Failure Type Code: 64
Ensure you have tried the following before you move to the next section
Reseat the effected drive, if the issue still persists move to next step