Volume not on preferred path reported on SG6060 StorageGRID appliance
Applies to
- NetApp StorageGRID
- NetApp SANtricity/E-Series
- SG6060 appliances
Issue
- Recovery GURU in SANtricity UI reports
Volume Not on Preferred Pathfollowing a back-end E-Series storage controller replacement. - StorageGRID UI reports:
Appliance storage controller hardware issueStorage appliance storage connectivity degraded
- On affected node, command
run-host-command multipath -lloutput shows secondary fail back path active but not ready:-
Command `multipath -ll` completed with code 0. Output: StorageGRID-PGE-Backup (XXXX) dm-19 NETAPP,INF-01-00 size=32G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | |- 16:0:0:254 sdbc 67:96 active ready running | `- 17:0:0:254 sdbu 68:128 active ready running `-+- policy='service-time 0' prio=10 status=enabled |- 15:0:0:254 sdak 66:64 active ghost running `- 14:0:0:254 sds 65:32 active ghost running
-