If ONTAP is upgraded, will Active IQ Unified Manager update which EMS messages it is automatically subscribed to on the cluster?

Views:
1
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
OM
Last Updated:

 

 

Applies to

Active IQ Unified Manager (AIQUM) 9.6+

Answer

When an ONTAP cluster monitored by Unified Manager (UM) is upgraded, on the next inventory collection it is assigned a new internal UUID in the UM database. With this new UUID the cluster is considered new to some UM processes, and UM will begin the subscription process for the automatically-subscribed EMS messages appropriate for that ONTAP version.

Note: Even though the cluster is considered new to UM after the upgrade, historical data will still be intact and there should be no noticeable effect to the user.

Additional Information

For more information, review the list of EMS events that are added automatically to Unified Manager.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.